Impedance: L, C, R, |Z| and phase angle
LCR Meters, Impedance Analyzers, Capacitance Meters
Impedance measured at the frequency and signal level the component will actually see in the product, not at a convenient default.
Impedance: L, C, R, |Z| and phase angle
- Category
- Electronic Measuring Instruments
- Form
- Benchtop / in-line
- Industries
- Electronic Components, Batteries
What this group is for.
Written as engineering fact. Nothing on this page states a specification the manufacturer has not supplied.
Test frequency and test signal level are set to the operating condition, because a component in tolerance at 1 kHz can be out of it where it will be used.
Four-terminal pair connection removes lead and contact impedance from the reading instead of averaging it in.
Measurement speed fast enough to sit in a production line at takt rather than beside it.
Sweeps that show the whole impedance curve, which is how a material or an electrode is characterized.
Highlighted models
Models engineers most often start from. The right one depends on the range you need to resolve and the conditions on site.
LCR Meter
IM3523A
|Z|, L, C, R from 40 Hz to 200 kHz
Ask about the IM3523A
Impedance Analyzer
IM7587
|Z|, L, C, R from 1 MHz to 3 GHz
Ask about the IM7587
C Meter
3506-10
Low capacitance at 1 kHz or 1 MHz
Ask about the 3506-10
Where it is used.
The situations this group is bought for, and the points on a real installation where it is connected.
- Incoming and outgoing inspection of capacitors, inductors and resistors.
- In-line component sorting and binning.
- Battery material and electrode characterization by impedance spectroscopy.
- R&D on magnetic components and dielectrics.
Typical measurement locations
Component impedance at the working frequency
Production line
A part in tolerance at 1 kHz can be out of tolerance where it will actually be used.
LCR Meters, Impedance Analyzers, Capacitance Meters: which one fits your measurement?
Give us the quantity, the range you need to resolve and the conditions on site. We will name the models that cover it and say plainly where they stop.
What Hioki commits to, for LCR Meters, Impedance Analyzers, Capacitance Meters.
The four criteria of innovation, read for this instrument group.
Increasing customer value
Production system
Component makers test at line speed. The production system is set up to supply instruments for a whole line, not one bench at a time.
Delivering peace of mind to customers
After-sales service
An impedance reading drifts with fixtures and cables before the meter. Support covers compensation and fixtures, not only the instrument.
Pursuing productivity and precision
Manufacturing capabilities
Repeatability at high speed is what a production test depends on. It is built and checked in manufacturing, instrument by instrument.
Creating new customer value
Collaborative development of new products
New materials and frequencies arrive before there is a standard way to measure them. Methods are developed with the makers who need them.